액체섬광계수기(LSC)

악취 및 유해물질분석실 연구장비 종류 및 담당자
사진
영문명/단축명 Liquid Scintillation Counter / LSC
모델명 Tri-Carb A4910TR
설치장소 악취 및 유해물질 분석실/ [81610]중앙방사성동위원소실험실
제작사 PerkinElmer
도입년도/가격 2017년 7월 / 54,000,000
담당자/연락처/e-mail 김재량(Kim Jaeryang) / 031-299-6760 / ryangryang91@skku.edu

 

♦ Features

 

• TR-LSC (Time-resolved Liquid Scintillation Counting)

for high sensitivity, low background liquid scintillation counting

• QuantaSmart™ Software

a robust multitasking, easy networking environment with unlimited assays in a secure multiuser environment

• SpectraWorks 2

-  spectral analysis package that determines optimal counting regions, and calculates figure of merit automatically

 

♦ Additional Options

 

• Alpha Beta Separation

-  via PSA Histogram and Dual PSA Discriminators improves accuracy for mixed and unknown samples containing isotopes with overlapping energies

 

♦ Specification

 

• Energy range: 0 - 2,000keV

• Efficienct normal count mode(Minimum acceptable)

- 3H: 0 - 18.6keV (63%)

- 14C: 0 - 156keV (95%)

• Observed background, Normal count mode(Average)

- 3H: 0 - 18.6keV (17 CPM)

- 14C: 0 - 156keV (26 CPM)

• Figure of merit(E2/B), Normal count mode

- 3H: 0 - 18.6keV (180)

- 14C: 0 - 156keV (360)

 

♦ Application Data

* 아래 파일명을 선택하시면 상세정보를 확인하실 수 있습니다.

• Environmental Sample Preparation for LSC